HUUM makes the Hive in 6 sizes, from 6 to 18 kW, for saunas of 177 ft³ to 989 ft³. Slide to your room size to see which one fits, how fast it heats and what it needs from your fuse box.

Updated Oct 17, 2026

Output

6–18 kW

Rooms

177 ft³–989 ft³

Stones

331 lb–551 lb

Sizes

6

Which size fits your sauna?

Your room's effective volume

459 ft³

106 ft³ – 1,165 ft³

Effective volume = inside volume, plus 1.2 m³ for every m² of glass, tile or stone; × 1.5 for solid log walls (Harvia's rule, used by most planners).

Sizes and specifications

ModelOutputRoom rangeStonesHeat-upPer session
HIVE Mini 66 kW177 ft³–318 ft³331 lb85–115 min$1.88
HIVE Mini 99 kW283 ft³–459 ft³331 lb60–80 min$2.22
HIVE Mini 1110.6 kW353 ft³–565 ft³331 lb55–75 min$2.39
HIVE 1212 kW424 ft³–636 ft³551 lb70–100 min$3.27
HIVE 1515 kW530 ft³–812 ft³551 lb60–80 min$3.70
HIVE 1818 kW636 ft³–989 ft³551 lb55–70 min$4.05

Heat-up and cost are our heat model's estimate for each size in a room at the middle of its range: indoor, insulated walls, 68 °F around the sauna, heated to 176 °F, one hour of bathing, electricity at $0.18/kWh (United States average).

Electrical connection

ModelSupplyCurrentFuse / breakerCable
HIVE Mini 61~ 240 V25 A30 A10 AWG
HIVE Mini 91~ 240 V37.5 A50 A8 AWG
HIVE Mini 111~ 240 V44.2 A50 A6 AWG
HIVE 121~ 240 V50 A2 × 30 A10+10 AWG
HIVE 151~ 240 V62.5 A2 × 50 A6+6 AWG
HIVE 181~ 240 V75 A2 × 50 A6+6 AWG

Current is computed from the output; fuse and cable are shown where the maker or dealer states them. A licensed electrician sizes and installs the circuit following the heater's manual and local rules.

Where to see it

Prices and availability come from the shop or maker and change; their page is what counts. Shop offers are added as retailers join.

Sources

Other heaters for the same rooms

Questions and answers

What size sauna does the HUUM Hive heat?

HUUM rates the sizes for these rooms: HIVE Mini 6 177 ft³–318 ft³; HIVE Mini 9 283 ft³–459 ft³; HIVE Mini 11 353 ft³–565 ft³; HIVE 12 424 ft³–636 ft³; HIVE 15 530 ft³–812 ft³; HIVE 18 636 ft³–989 ft³. Use your room's effective volume: add 1.2 m³ for every m² of glass, tile or stone, and multiply by 1.5 for solid log walls.

What fuse or breaker does the HUUM Hive need?

It depends on the size and your supply: HIVE Mini 6: 1~ 240 V: 25 A (30 A); HIVE Mini 9: 1~ 240 V: 37.5 A (50 A); HIVE Mini 11: 1~ 240 V: 44.2 A (50 A); HIVE 12: 1~ 240 V: 50 A (2 × 30 A); HIVE 15: 1~ 240 V: 62.5 A (2 × 50 A); HIVE 18: 1~ 240 V: 75 A (2 × 50 A). A licensed electrician sizes the circuit from the heater's manual and local rules.

How long does the HUUM Hive take to heat up?

In a well-insulated indoor room at the middle of each size's range, our heat model gives: HIVE Mini 6 85–115 min; HIVE Mini 9 60–80 min; HIVE Mini 11 55–75 min; HIVE 12 70–100 min; HIVE 15 60–80 min; HIVE 18 55–70 min to reach 176 °F. Outdoor saunas, glass and cold weather take longer.

How many stones does the HUUM Hive take?

As stated by HUUM: HIVE Mini 6 331 lb; HIVE Mini 9 331 lb; HIVE Mini 11 331 lb; HIVE 12 551 lb; HIVE 15 551 lb; HIVE 18 551 lb. Use the stone size the manual specifies and re-stack the stones at least once a year, replacing crumbled ones.